Subscribe Twitter FaceBook

Pages

Friday 8 July 2011

Flow Meters Comparison

A comparison table of commonly used flow meters based on the viscosity of fluids that they can handle and for which type of fluid they are suitable, working conditions , accuracy , range are given below 


Sr no
Type
Viscous liquid
Slurry
Gas
Output
Pressure
loss
Accuracy% full scale
Full range
1
Orifice
Limited
Poor  
Good
Square root characteristic
High
±0.5to ±2%
10-3to 5.5×103m3/hr
2
Venturi
Limited
Limited
Good
--do--
Minimal
±0.5to ±3%
1to 5.5×103m3/hr
3
Flow nozzle
Limited
Limited
Good
--do--
Minimal
±0.5to ±3%
1to 5.5×103m3/hr
4
Pitot tube
Poor
Poor
Good
--do--
Poor
±5to ±10%
10 to 104m3/hr
5
Electromagnetic
Good
Good
Good
Linear
Minimal
±2to ±5%
5.5×10to 4.95×103m3/hr
6
Variable area meter
Limited
Limited
Good
Linear
Average
±0.5%
10-7to 5.5×103m3/hr
7
Positive displacement
Good
Good
Good
Linear
Minimal
±0.5to ±1%
10-5to 5×10m3/hr
8
Turbine
Limited
poor
Poor
Linear
Minimal
±2to ±5%
05 to 4.95×102m3/hr